SEMPAL

Manufacturer of modern
energy efficient equipment for metering
and regulation of thermal energy and water

SVTU-11T ultrasonic heat meter

FOR OF HEAT MEASURING ON APARTMENT HOUSES AND OTHER BUILDINGS WITH HORIZONTAL TYPE OF HEATING WIRING.

Devices measure volume, mass, excessive pressure of water or liquids with solids (not more than 200 mkm).

  • Accuracy degree – class 1, 2 (depends on performance);
  • Case material – stainless steel, steel 20;
  • Connection – flange;
  • DN – 20 mm – 400 mm;
  • Powering – battery (3.6 V);
  • Service life – not less than 12 years;
  • Warranty – 4 years.

Desription

The device accounts, displays and saves temperature, volume and mass of water. Saving provides in archives (hourly, daily, monthly, yearly). Ultrasonic waves emit in the flow direction and against. Based on time difference volume of water flow calculates. 

SVTU-11 Т has a range of features:

  • Flow meter section made of stainless steel;
  • Flow sensors made of titan (excludes pollution and accuracy reducing);
  • There is possibility to produce flow node and temperature sensors for flooded places;
  • Various packets performance for flow sensors tie-in with pressure to 16 atm;
  • Standard package includes flanges (or clumping nuts), paronite gasket, fixing. For DN to 40 mm – straight sections (after 40 mm – by request);
  • Device can provide flow measurement few times per second for accuracy increasing;
  • Maximum cable length from computer to SVTU-11 Т sensors – 30 m. Maximum cable length to PC – 50 m. It allows to put out the computer from heat point to other place for comfortable working;
  • We supply devices for Ukraine utilities and abroad.

To get more information about equipment and performance options contact us by phone numbers:

Technical specifications

Measurement unit:

Due the installation you can choose:
GJ, kWh, MWh, GCal.

Thermal power displayed by units:
MW for energy units GJ, kWh, MWh;
GCal/h for energy units GCal.

Temperature range of heat carrier

2…150 °C

Temperature difference range of heat carrier

3…150 °C

Environment temperature range of heat carrier

5…55 °C

Pressure PN, kgs/cm2

16 bar

Battery

3.6 V, lithium

Battery change interval

6 years

Data reading

By IrDA connector;
RS 232 built-in.
Possibility to install additional expansion module:
RS 485 (Sempal/Modbus protocol);
M-Bus (external module).

Display

LCD, 8 categories + text row

Materials

Flow meter section:
DN 20 – 150 – stainless steel;
DN 150 – 400 steel 20 (stainless steel on request).

Computer case – plastic.

Protection degree

Computer case – IP65;
Flow meter section – PI 68.

Accuracy degree (by EN1434)

Class 2

Environment degree for device working

"C" by EN1434:
• Temperature – 5..55 Cº;
• Normal humidity;
• Electromagnetic obstacles – class C;
• Mechanical workload to computer – low.

Archiving

The device has nest types:

  • Hourly (depth to 1680);
  • Daily (depth to 500);
  • Monthly (depth to 36);
  • Yearly (depth to 16).

Maximum power and flow rates

Accounting of maximum values based on average values for fixed period of time. Possible average interval is from 1 minute to 30 minutes.
Archives save maximum value

Temperature sensors

Depends on order.

 

Type
DN

Sensitivity
threshold

Lower
border
consumption

Transitional
cost

Long-lasting
cost

Upper
limit
costs

Borderline
cost

[m3/h]

[m3/h]

[m3/h]

[m3/h]

[m3/h]

[m3/h]

20 0,03 0,06 0,1 6,3 8 10
25 0,05 0,10 0,16 10 12,5 16
32 0,13 0,25 0,4 25 32 35
40 0,20 0,40 0,64 40 50 60
50 0,32 0,63 1,0 63 80 90
65 0,50 1,00 1,6 100 125 150
80 0,80 1,60 2,6 160 200 240
100 1,25 2,50 4,0 250 320 360
125 2,00 4,00 6,4 400 500 900
150 3,15 6,30 10 630 790 1200
200 5 10 16 1000 1250 2200
250 10 20 32 2000 2500 3500
300 12,5 25 40 2500 3125 5000
350 17,5 35 56 3500 4375 7000
400 20,0 40 64 4000 5000 9000