SVTU-11 RP HEAT METER
FOR OF HEAT MEASURING ON APARTMENT HOUSES AND OTHER BUILDINGS WITH HORIZONTAL TYPE OF HEATING WIRING.
SVTU-11 RP allows to define quantity of heat energy. And ultrasonic working principle ensures long lasting reliable work without degradation of main technical characteristics.
- Accuracy degree – class 2;
- Case material – brass/ stainless steel;
- Connection – carving/ flange;
- DN – 15 mm – 100 mm;
- Powering – battery (3.6 V);
- Service life – 16 years;
- Warranty – 4 years.
Desription
The device accounts, displays and saves temperature, volume and mass of water. Saving provides in archives (hourly, daily, monthly, yearly). Ultrasonic waves emit in the flow direction and against. Based on time difference volume of water flow calculates.
Included in the delivery package:
- Flow meters - DN15-100. There are made from brass or stainless steel with anti-corrosion coating. There is IP-68 protection degree. - 2-piece;
- Flow meters DN32 – 40 (equipped with straight sections);
- Flow sensors – 2-piece. For two-channel – 4-piece4
- Temperature sensors (equipped with protection sleeves) – 1-piece, if device is used to account hot water;
- Cables from electronic block to TS-1.15, 2, 3-20 m, 1 m increments, or to another flow measuring section;
- The heat meters are identical by overall dimensions to modern European manufacturers. It makes possible to replace water meters without usage of straight sections;
- SVTU-11 RP electronic block. Case made of plastic. Protection degree – IP-65. – 1-piece;
- Water meters have a 4-tariff accumulator which is possible to print data for chosen tariff.
To order or get advice about device installation contact us by phone numbers:
Technical specifications
Measurement unit: |
Due the installation you can choose: Thermal power displayed by units: |
Temperature range of heat carrier |
2…150 °C |
Temperature difference range of heat carrier |
3…150 °C |
Environment temperature range of heat carrier |
5…55 °C |
Pressure PN, kgs/cm2 |
16 |
Battery |
3.6 V, lithium |
Battery change interval |
16 years |
Data reading |
Through IrDA head.
|
Display |
LCD, 8 categories + text row |
Materials |
Flow meter section: Computer case – plastic. |
Protection degree |
Computer case – IP65; |
Accuracy degree (by EN1434) |
Class 2 |
Environment degree for device working |
"C" by EN1434: |
Archiving |
The device has nest types:
|
Maximum power and flow rates |
Maximum rate accounting provide by average value with preset time interval You can install average time interval from 1 minute to 30 minute during device installation. |
Temperature sensors |
Pt1000, two-wire connection. |
Type DN |
Nomin. |
Min. |
Max. |
Threshold |
Limit value |
Loss |
Joining |
Length |
[m3/h] |
[m3/h] |
[m3/h] |
[m3/h] |
[m3/h] |
[bar] |
[inch] |
[mm] |
|
15A |
1,5 | 0,015 | 3 | 0,003 | 5 | 0,17 | G ¾ B | 110 |
20A |
1,5 | 0,015 | 3 | 0,003 | 5 | 0,1 | G 1 B | 130 |
20С |
2,5 | 0,025 | 5 | 0,005 | 7 | 0,1 | G 1 B | 130 |
25А |
3,5 | 0,035 | 7 | 0,007 | 10 | 0,12 | G 1 ¼ B | 160 |
25С | 3,5 | 0,035 | 7 | 0,007 | 10 | 0,08 | G 1 ¼ B | 160 |
25D | 6 | 0,06 | 12 | 0,012 | 14 | 0,22 | G 1 ¼ B | 160 |
32А (В) | 15 | 0,15 | 20 | 0,05 | 30 | 0,09 | Flange ⌀84 мм |
180 |
32С (D) | 15 | 0,15 | 20 | 0,05 | 30 | 0,09 | М48х2 | 180 |
40D (E) | 25 | 0,25 | 35 | 0,05 | 50 | 0,1 | Flange ⌀98 мм |
200 |
40A (B) | 40 | 0,4 | 50 | 0,08 | 80 | 0,25 |
Flange |
200 |
40С | 40 | 0,4 | 50 | 0,13 | 80 | 0,25 | G 2 B | 200 |
50А | 35 | 0,35 | 50 | 0,13 | 80 | 0,07 | Flange ⌀122 мм |
180 |
65А (В) | 100 | 1,0 | 125 | 0,20 | 270 | 0,17 | Flange ⌀144 мм |
200 |
80А | 160 | 1,6 | 200 | 0,32 | 390 | 0,11 | Flange ⌀155 мм |
210 |
100А | 250 | 2,5 | 320 | 0,50 | 610 | 0,09 |
Flange |
230 |